162 NARECSEG(1)
D Name of remote device for use with -a option.L_RC
CONFIGURATION OPTIONS
enarecseg.segment.framesiz
The signal energy is computed every framesize samples. [100]
narecseg.segment.overlap
The number of frames of length framesize used for energy computations. This
must be an integer >= 1. [4]
hnarecseg.segment.head.thres
Threshold for preliminary determination of beginning of a segment in dB above
the background level. [5.0]
hnarecseg.segment.body.thres
Threshold for definite determination of beginning of a segment in dB above
background. [14.0]
hnarecseg.segment.tail.thres
Threshold for determination of end of a segment. [10.0]
narecseg.segment.head.maxTime
Maximum time between preliminary and definite determination of a segment in
seconds. [0.075]
enarecseg.segment.minTim
Minimum duration of a segment. [0.15]
narecseg.segment.gap.minTime
Minimum time between segments. [0.12]
narecseg.segment.extendTime
Time to extend ends of segments. [0.1]
]
n
narecord.AutoStart True to automatically start/stop DAT machine. [off
arecord.filter.resp.nn.mm
If non-null, the specification of filter response for sample-rate converter which
n
u
converts from nn to mm samples/second. See the User’s Manual for details o
sing this option. [NULL]
narecord.stopband.atten
Attenuation, in dB, of sample-rate converters anti-aliasing stopband. [90]
SEE ALSO
narecord(1) netaudiod(8),
.
N
DAT-Link User’s Manual
etAudio Reference Last change: 1992/11/22 2