Trimble R6/R7 GPS and Trimble R8 GNSS Receivers User Guide 117
Default Settings 18
Trimble R6 GPS and R8 GNSS Receiver Operation
182.1 Default behavior
The factory defaults specified above are applied whenever you start the receiver. If a
power up file is present in the receiver, its settings are applied immediately after the
default settings, so you can use a power up file to define your own set of defaults.
182.2 Power up settings
When you turn off the receiver, any changes that you have made to logging settings are
lost and these settings are returned to the factory defaults. Other settings remain as
defined in the current file. The next time you turn on the receiver, the receiver checks
for a power up file and, if one is present, applies the settings in this file.
When you turn the receiver
on and …
then logging settings
are …
and logging …
it is the first time that the
receiver has been used
the factory defaults does not begin
automatically
you have reset the receiver to its
factory defaults
the factory defaults, or
those in the power up file
a
a
A factory default setting is used only if the setting is not defined in the power up file.
does not begin
automatically
you have performed a full reset the factory defaults,
because resetting deletes
any power up file
does not begin
automatically
When you use [P] to turn off and
then turn on the receiver and …
then logging settings
are …
and all other settings
are …
you changed the receiver settings
by applying an application file
the factory defaults the last settings used
you changed the receiver settings
using configuration software
the factory defaults the last settings used
there is a power up application file
in the receiver
the factory defaults, or
those in the power up file
a
a
A factory default setting is used only if the setting is not defined in the power up file.
the last settings used, or
those in the power up file