EasyManuals Logo

Trimble R6 User Manual

Default Icon
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
9 Default Settings
62 Trimble R6/R7 GPS and Trimble R8 GNSS Receivers User Guide
Trimble R7 GPS Receiver Operation
93.3 Logging after power loss
If the Trimble R7 GPS receiver loses power unexpectedly, when power is restored the
receiver tries to return to the state it was in immediately before the power loss. The
receiver does not reset itself to defaults or apply any power up settings. If the receiver
was logging when power was lost unexpectedly, it resumes logging when power is
restored.
However, when you turn off the receiver using
[P], the receiver behaves as if you pressed
[D] to stop logging before you pressed [P]. In this case, when power is restored normally,
logging does not begin until you start it manually.
93.4 Disabling logging
To disable logging, you can set the receiver’s data logging and position logging rates to
Off. However, if you press
[D] while logging is disabled, the receiver will still log data,
using the default logging settings.
you changed the receiver
settings using configuration
software
the factory defaults the last settings used
there is a power up
application file in the receiver
the factory defaults, or those
in the power up file
a
the last settings used, or those
in the power up file
a
a
A factory default setting is used only if the setting is not defined in the power up file.
When the receiver is logging
data and then loses power
then when power
is restored, data
logging
and logging
settings are
and all other
settings are
unexpectedly resumes
automatically
the last settings
used
the last settings
used
when you press
[P] does not resume the factory
defaults
the last settings
used
When you have disabled logging then if you press [D] to start logging,
logging settings are
using the Trimble Survey Controller or GPS
Configurator software
the factory defaults
in the power up application file the factory defaults
When you use [P] to turn
the receiver off then on
again and
then logging settings
are
and all other settings
are

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trimble R6 and is the answer not in the manual?

Trimble R6 Specifications

General IconGeneral
BrandTrimble
ModelR6
CategoryGPS
LanguageEnglish

Related product manuals