Model 3440-L 6–31
6. SPECIAL FUNCTIONS
SPECIAL ROADWAY
After taking readings and pressing STORE, operators can let the gauge
prompt them for the information required on U.S. FHWA projects. The
gauge can then download the readings and other information to a computer
or serial printer.
When shipped from the factory, the default storage mode is the standard
storage mode. To change the storage mode, select the Special Rdwy option
on the Special function menu. The gauge will display the current status.
Press SHIFT and SPECIAL, then 1 4 for:
Special Roadway
Mode:
OFF
Want to change?
The YES key toggles the function on and off. To accept the displayed
status, press NO/CE. Once the storage mode is changed, the gauge will
remain in this mode until it is changed again.
In both the Asphalt and Soil mode, the gauge can prompt the operator for:
FHWA number
Station number
Distance from centerline
Lane direction
Elevation above original ground
Elevation below finished grade
Compaction method
In the Asphalt mode, the gauge can prompt the operator for:
Lift number
Lift thickness
Test type (surface mix, intermediate mix, or base mix)
In the Soil mode, the gauge can prompt the operator for:
Test type (soils or stone)
Further test type (embankments, pipe backfill, subgrade, abutment
backfill, retaining wall, or rockfill)
If backfill, then pipe size
If soil, then density required

Table of Contents