5–16
STATUS FUNCTION
The Status function lets the operator check all gauge settings without
executing the particular function. Press SHIFT and STATUS for the
display:
-CONTROL STATUS-
Press YES to
view settings.
(CE to exit)
Press YES to display:
UNITS: xxx
TIME: xxxx
MODE: xxxx
(Press YES)
Press YES to display:
MA=x.x PCF
PR=xxx.x PCF
VD=xxx.x PCF
(Press YES)
Press YES to display:
D OFF: x.x
TRUE %M=x.x %
GAUGE %M=x.x %
(Press YES)
Press YES to display:
AUTO-STATION:OFF
(Press YES)
Press YES to display:
Target Prec.-
(Press YES)
Press YES to display:
Depth- xxxx
Calib- xxxx
(Press YES)
Press YES to return to the first status display. Press NO/CE to return to
the READY display.