EasyManuals Logo

Troxler 3440-L User Manual

Troxler 3440-L
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
5–22
RECALL FUNCTION
The Recall function allows the operator to review the last density and
moisture readings.
To execute the Recall function, press SHIFT and RECALL. If the
gauge is in Soil mode, the display will be:
%PR=xxxxx %
DD=xxxxx PCF
WD=xxxxx PCF
M=xxxxx %M=xxxxx
If the gauge is in Asphalt mode, the display will be:
%MA=xxxxx %
WD=xxxxx PCF
M=xxxxx %M=xxxxx
%VOIDS=xxxxx%
DEPTH FUNCTION
The Depth function allows the operator to select one of two depth modes:
manual or automatic. In the Manual mode, the gauge prompts the operator
to manually input the source rod depth using the keypad. In the Automatic
mode, the gauge automatically reads the depth strip on the index rod, and
then determines the source depth. To set the Depth mode, press SHIFT
and DEPTH.
MANUAL MODE
If the Depth mode is set to Automatic, the gauge display is:
Depth Ind: Auto
1- Select MANUAL
2- Calibrate
(CE to exit)
To set the Depth mode to Manual, press 1 for:
Depth Indicator:
MANUAL