5. 3440 OPERATIONS
PROCTOR/MARSHALL/VOIDLESS FUNCTION
The 3440-L gauge provides for up to four different Proctor values, four
different Marshall values, and one Voidless density value to be stored for
later use. These values are used to determine percent compactions. The
percent compaction calculations for Soil and Asphalt modes are as follows:
Soil mode (DD
÷
PR)
×
100 = %PR
Asphalt mode (WD
÷
MA)
×
100 = %MA
Asphalt mode 100 – [(WD
÷
VD)
×
100] = %VOIDS
To select or change a Proctor, Marshall, or Voidless density value, press
the PROCTOR/MARSHALL key for the display:
MA=xxx.x PCF
PR=xxx.x
VD=xxx.x
Want to change?
If not, press NO/CE. Then press START/ENTER. The screen reverts
to the READY display.
If a value is to be enabled, or a new value added or changed, press YES.
The display is:
Select:
1 - MA
2 - PR
3 - Voidless
NOTE
After selecting Marshall (MA) or Proctor (PR) from the above
display, the steps for the selecting the Marshall and Proctor
values are identical. Therefore, this manual illustrates only
the Marshall value selection screens.
To change a Marshall value, press 1 to display:
Select source of
Marshall value:
1- Stored value
2- New value