LCD MESSAGES LIST
Soft Start : Battery Charger progressive Start;
Float : Battery charger in Float mode;
Equalize: Battery charger in Equalize mode;
Formation : Battery charger in Formation mode;
Current Limit1 : Battery charger in Float Current Limit mode;
Current Limit2 : Battery charger in Equalize Current Limit mode;
Current Limit3 : Battery charger in Formation Current Limit mode;
AC OUT : Message in case of AC failure;
VAC1, (VAC2 & VAC3 for 3 Phase system) : AC Voltage readings;
IAC1, (IAC2 & IAC3 for 3 Phase system) : AC Current readings;
IBatt : Battery Current;
Battery Test Run : The charger is in Battery Test Mode;
Batt Test Stop : Battery Test Stopped;
Formation Start : The charger is in Battery Formation Mode;
Formation Sop : Formation mode stopped;
Not Available! : Active function not applicable for your system;
Not Permitted! : Test interrupted because test conditions are not verified;
Are You Sure? : Confirm active operation;
Synchro Ok : Synchronization succeeds ;
Save? : Confirm value modification;
Reset (…) Ok : Reset operation for active function (…) succeeds;
Batt High Volt : Battery High Voltage alarm;
Batt Low Volt : Battery Low Voltage alarm;
Grou
nd Fault + : Positive Ground Fault alarm;
Ground Fault - : Negative Ground Fault alarm;
AC Fail : AC Failure alarm;
Rectifier Fail : Rectifier Failure alarm;
Rect High Volt : Rectifier High Voltage alarm;
HV Shutdown : High Voltage Shutdown alarm;
Rectif Low Volt : Rectifier Low Volt alarm;
Charger HighTemp : Charger High Temperature alarm;
Charger Low Temp : Charger Low Temperature alarm;
Battery HighTemp : Battery High Temperature alarm;
Battery Low Temp : Battery Low Temperature alarm;
AC High Voltage : AC High Voltage alarm;
AC Low Voltage : AC Low Voltage alarm;
High Ripple : High Ripple alarm at the DC output;
Rect Low Current : Rectifier Low Current alarm;
Rect HighCurrent : Rectifier High Current alarm;
Batt Low Current : Battery Low Current alarm;
Batt HighCurrent : Battery High Current alarm;
High Capacity : Battery High Capacity alarm;
Low Capacity : Battery Low Capacity alarm;
PCOM Fail : Communication alarm problem between PCOM (communication board) and control board;
PM Fail : Communication alarm problem between PM (Measurements board) and control board;
Frequency Fail : Frequency Failure alarm;
Defective Cell : Defective cell for unbalanced battery alarm;
Defective Probe: Defective temperature probe (probe shorted);
Ba
tt Discharging: Battery is Discharging (Battery is providing current to the load);