D-302756 31
Group Abbr. Events Reported
Alarms alrm Fire, Burglary, Panic, Tamper
Open/close o/c Arming AWAY, Arming HOME, Disarming
Alerts Alrt No-activity, Emergency, Latchkey
Maintenance - Low-battery AC failure
"Alarm" group has the highest priority and "Alert" group has the lowest priority.
The selectable options are as follows:
Plan name Sent to center 1 Sent to center 2
"all -o/c J backup" All but open/close
All but open/close if center 1 doesn’t respond
"all J all" All All
"all-o/c J all -o/c " All but open/close All but open/close
"all –o/c J o/c " All but open/close Open/close
"all (–alrt) J alrt" All but alerts Alerts
"alrm J all (–alrm)" Alarms All but alarms
"disable report" Nothing Nothing
"all J backup" All All if cent. 1 doesn’t respond
Note: “All” means that all 4 groups are reported and also trouble messages - sensor / system low battery, sensor
inactivity, power failure, jamming, communication failure etc.
4.7.3.1 Configuring the Types of Events to be Reported
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
3.
or
4.
5.
6.
or
Select between "all-o/c* backup", "all *all", "all-
o/c*all-o/c", "all-o/c*o/c", "all(-alrt)*alrt",
"alrm*all(-alrm)", "disable report" and "all *backup".
7.
You can now press the button to take you to the "
1st RPRT
METHOD
" menu, or press the button to take you to "
<OK> TO
EXIT
".
4.7.3.2 Configuring the Communicators Report Sequence
Continue below from the previous section or repeat steps 1 to 4 of section 4.7.3.1 before continuing with the
following instructions:
1.
REPORT EVENTS
REPORT EVENTS
all-o/c*backup
REPORT EVENTS
3:C.S. REPORTING
1:PSTN/GSM
DEFINE COMM.