10
VERSION 03/2020 ORDER NUMBER DOC2330732
VU 1/VU 2/VU 3
3 IDENTIFICATION
3.1 EXPLOSION PROTECTION IDENTIFICATION
Device type: VU 1/VU 2/VU 3 reciprocator
Manufacturer: J. Wagner GmbH
88677 Markdorf
Germany
II 3D IIIB T 135 °C IP54 0 °C ≤ Tamb ≤ +40 °C
Ex: Symbol for explosion protection
II: Device class II
3: Category 3
D: Ex-atmosphere dust
IIIB: Explosion group (dust group)
T 135 °C Temperature class (T < 135 °C)
IP 54 IP Code
Tamb Permissible ambient temperature
3.2 PERMISSIBLE DEVICE COMBINATIONS
WARNING
Incorrect use!
Risk of injury and damage to the device.
Only connect the reciprocator to original WAGNER devices.
The reciprocator type series VU 1, VU 2 and VU 3 can be controlled with the following controllers:
MCS 1 movement control module (stand-alone operation)
ProTech S
ProTech M (not for VU 3)
PrimaTech CCM with MCS 1 movement control module
The reciprocator type series VU 1, VU 2 and VU 3 can be combined with the following devices:
Only VU 1/VU 2: Sliding units of the type series HU 1-xxxx, HU 1-xxxx M, RS 8-xxxx
PEA-C4, PEA-T3 type series guns
Only VU 1/VU 3: Z-axes
For this purpose, the notices regarding the correct gun arrangement in Chapter 6.11 and
Chapter6.12 are to be observed!
Further devices can be combined depending on the project specics.
Please determine permissibility within the framework of the project.