Commissioning
6.5 Commissioning the vehicle
102
Operator’s Manual | 4080T Basic Line | 1000408123 | 05/2019 | [en]
Fig.79: Move starting key to position
0
1. Retract the loader unit and lower it to the ground.
2. Secure the vehicle with the parking brake.
3. Switch off all electric consumers.
4. Allow the engine to idle for approx. three minutes.
5. Move starting key to position 0.
6. Remove the starting key.
6.5.7
Jump-starting the engine
WARNING
Connecting the jumper cable to the negative terminal of the dis-
charged battery can lead to accidents.
Batteries can release oxyhydrogen gas, which can easily ignite if sparks
form and cause serious injury.
► Do not connect the jumper cable to the negative terminal of the dis-
charged battery.
NOTICE
The electrical system can be damaged by a short-circuit when start-
ing from another source.
► Make sure that both vehicles do not touch each other.
► Do not jump-start the vehicle if the battery is malfunctioning or
frozen.
► Do not connect two batteries in series.
► Use starting aid batteries with the same voltage.
► Use tested jumper cables with sufficient cross-section and insulated
terminal clamps.
► Route jumper cable so that they cannot be caught by starting or ro-
tating parts in the engine compartment.