PROCEDURE
1 Put the insulation bandage (001, Figure 7-10) around the water channel on the cylinder
liner.
2 Make sure that there is an overlap of approximately 30 mm.
3 Put the plate (003) over the insulation bandage (001).
4 Use the lever chain hoist to attach the tension springs (002).
5 Make sure that there is a clearance of 10 mm between the ends of the plate (003).
Fig 7-10 Insulation bandage
6 Attach the flanges (004, Figure 7-11) (part of the lifting tool) (006) to the cylinder liner
(001) with the screws (002).
7 Operate the engine room crane (007) to lower the lifting tool (006) on to the cylinder
liner (001).
8 Apply copper paste to the threads of the screws (005).
NOTE: The connection between the lifting tool (006) and the cylinder liner (001)
relates to the engine.
9 Torque the screws (005) to the related value, refer to section 16.1 Tightening
instructions.
10 Apply oil to all new O-rings.
11 Attach the new O-rings to their applicable positions.
X72DF
AA00-2124-00AAA-720A-A
Maintenance Manual Cylinder liner - install
Winterthur Gas & Diesel Ltd.
- 189 - Issue 002 2020-10

Table of Contents

Other manuals for WinGD X72DF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WinGD X72DF and is the answer not in the manual?

WinGD X72DF Specifications

General IconGeneral
BrandWinGD
ModelX72DF
CategoryEngine
LanguageEnglish

Related product manuals