EasyManua.ls Logo

WinGD X72DF - Proximity Sensor - Remove

WinGD X72DF
902 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROCEDURE
1 Disconnect the electrical connection from the applicable proximity sensor (002, Figure
12-17).
2 Loosen the lock-nut (003).
3 Remove the proximity sensor (002) from the sensor adapter (001).
Fig 12-17 Proximity sensor - remove
ZS5401C - DRVING END
00584
002
I
I
I - I
ZS5405C - FREE END
003
001
CLOSE UP
None
X72DF
AA00-7762-00AAA-520A-A
Maintenance Manual Electric balancer sensor unit - remove the proximity sensor