PROCEDURE
1 Disconnect the power supply to the defective MCM-11 on the related cylinder.
NOTE: WinGD recommends to make a software back-up from the LDU-20. This will
make sure that the correct configuration is loaded. For more data, speak to or
send a message to WinGD.
2 Remove the defective MCM-11.
3 Attach an UNSERVICEABLE label to the MCM-11.
CLOSE UP
None
X72DF
AA00-9606-00ACA-520A-A
Maintenance Manual MCM-11 - remove
Winterthur Gas & Diesel Ltd.
- 817 - Issue 002 2020-10