111
MOTIF XS6/MOTIF XS7/MOTIF XS8
TEST PROGRAM
Tests Overview
Number
Item Measurement Conditions, etc. Test Code
T00-1
MAC Address Read/Write Write/Read MAC Address
A02200
T01
EBUS ID Check OK/NG Read each EBUS ID
A02100
T02
LCD,LED Visual check LCD: Color, white/black LED: ALL on/off
A00200
T03
Panel Switch, LED OK/NG with TONE (1 KHz)
A00400
T04
Encoder OK 0 – +8 – -8
A00500
T05
Knob OK 0 – 127 – 64
A00600
T06
Slider OK 0 – 127
A00700
T07
1KeyOn OK KeyCode=C3
A00800
T08
Keyboard After Touch OK/NG With TONE (1 KHz) 127 – 0, offset (XS8 only)
A00900
T09
Pitch Bend Wheel OK 64 – 127 – 0
A00A00
Modulation Wheel 0 – 127
Ribbon Controller [0 – 15] – [90 – 112] – off[113 – 127]
T10
Foot Controller 1,2 OK 0 – 127
A00B00
Foot Switch 0 – 1
Assignable 0 – 1
Sustain(FC3) 35 – 101
T11
MIDI In/Out/Thru OK/NG Check Thru (except MIDI Mode)
T12
USB to DEVICE OK/NG Device identifi cation test (USB Memory)
A00C00
T13
USB to HOST OK/NG USB loop test with “TO DEVICE” side
A00D00
T14
1KHz OUTPUT-L output Measurement OUTPUT(L)=+5.0 ± 2 dBu, (R)=-85.0 dBu or less (10 KΩ)
A00E00
AS-OUT(L)=+4.0 ± 2 dBu, (R)=-85.0 dBu or less (10 KΩ)
DIGITAL OUT-L PHONES(L)=-2.0 ± 2 dBu, (R)=-70.0 dBu or less (33 Ω)
T15
1KHz OUTPUT-L output Measurement OUTPUT(R)=+5.0 ± 2 dBu, (L)=-85.0 dBu or less (10 KΩ)
A00F00
AS-OUT(R)=+4.0 ± 2 dBu, (L)=-85.0 dBu or less (10 KΩ)
DIGITAL OUT-R PHONES(R)=-2.0 ± 2 dBu, (L)=-70.0 dBu or less (33 Ω)
T16
AD
g
DA (MIC) Measurement OUTPUT(L)=+4.0 ± 2 dBu, (R)=-60.0 dBu or less (10 KΩ)
A01000
Lch INPUT SW
T17
AD
g
DA (LINE) Measurement OUTPUT(R)=+4.0 ± 2 dBu, (R)=-70.0 dBu or less (10 KΩ)
A01100
Rch INPUT SW
T18
DIMM OK/NG Capacity +R/W
A01900
T19
DIMM OK/NG Full Test
A01A00
T20
ROM OK/NG SYSTEM ROM ID Read
A01B00
OK/NG WAVE ROM Data Read
T21
SYSTEM RAM OK/NG R/W
A01C00
EFFECT RAM
T22
mLAN OK/NG In addition, audibly check stereo output
A01D00
T23
ETHERNET OK/NG Read/Write
A02000
T24
Factory Set OK Initialized condition/with factory set caution descriptions
A01E00
T25
Exit(Noise Level) Measurement OUTPUT (L, R)= -90.0 dBu or less (10 KΩ)
A01F00
AS-OUT (L, R)= -90.0 dBu or less (10 KΩ)
(R)=-90.0 dBu or less (33 Ω)
Measurement Conditions
To test the unit in MANUAL MODE, the following measuring instruments and jigs are required.
Measuring Instruments:
Frequency counter, Oscilloscope, Level meter (with JIS-C curve), Distortion factor meter, Oscillator, etc.
Jigs:
PC
∗1
, MIDI cable, DIMM memory board, mLAN16E2 (mLAN option board: XS6, 7), USB memory (2.0), USB cable (A-B
Type), Ethernet cable (LAN cable), Keyboard amplifier, MD player (w/digital inputs), Wired LAN router (w/DHCP server
function [Ex.: Buffalo BBR-4MG]), Foot pedal (FC3), Foot switch (FC4 or FC5), Foot controller (FC7), IEEE1394 repeater
hub
∗2
[Ex.: Sanwa Supply 1394-RP2GPH], IEEE1394 cable
∗2
, etc.
∗1
: Used in “T00-1 MAC Address Read/Write”.
Operating environment: Pentium 200 MHz or faster, Windows 2000/XP Home Edition/XP Professional
∗2