3.22 Parameters Changed by E5-01 [PM Motor Code Selection]
208 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
No. Name Unit Motor Code (setting value of E5-01)
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.092 0.076 0.051 0.066 0.075 0.083
n5-02
Motor Inertia Acceleration
Time
s 0.092 0.076 0.051 0.066 0.075 0.083
n8-49 Heavy Load Id Current % -8.6 -11.5 -10.3 -19.8 -8.5 -11.0
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
Table 3.12 SSR1 Series Motor Code Setting for Specification of 400 V at 1750 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 123B 123D 123E 123F 1240 1242
Voltage Class V 400 400 400 400 400 400
Capacity kW 7.5 11 15 18.5 22 30
Motor Rotation Speed min
-1
1750 1750 1750 1750 1750 1750
E5-02 PM Motor Rated Power kW 7.5 11.0 15 18.50 22.00 30.00
E5-03
PM Motor Rated Current
(FLA)
A 13.65 20.7 27.5 33.4 39.8 52.0
E5-04 PM Motor Pole Count - 6 6 6 6 6 6
E5-05
PM Motor Resistance (ohms/
phase)
Ω 0.786 0.349 0.272 0.207 0.148 0.235
E5-06
PM d-axis Inductance (mH/
phase)
mH 16.49 13.17 10.30 8.72 6.81 5.4
E5-07
PM q-axis Inductance (mH/
phase)
mH 23.46 15.60 12.77 11.22 8.47 7.26
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad 520.0 481.5 498.8 509.5 503.9 561.7
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 87.5 87.5 87.5 87.5 87.5 87.5
E1-05 Maximum Output Voltage V 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 87.5 87.5 87.5 87.5 87.5 87.5
E1-09 Minimum Output Frequency Hz 4.4 4.4 4.4 4.4 4.4 4.4
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.077 0.084 0.102 0.101 0.098 0.130
n5-02
Motor Inertia Acceleration
Time
s 0.077 0.084 0.102 0.101 0.098 0.130
n8-49 Heavy Load Id Current % -18.6 -12.5 -15.5 -17.9 -15.1 -16.8
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
Table 3.13 SSR1 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 1302 1303 1305 1306 1308 130A
Voltage Class V 200 200 200 200 200 200
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5
Motor Rotation Speed min
-1
1450 1450 1450 1450 1450 1450
E5-02 PM Motor Rated Power kW 0.4 0.75 1.5 2.2 3.7 5.5
E5-03
PM Motor Rated Current
(FLA)
A 1.88 3.13 5.63 8.33 14.17 20.63
E5-04 PM Motor Pole Count - 6 6 6 6 6 6
E5-05
PM Motor Resistance (ohms/
phase)
Ω 3.190 1.940 1.206 0.665 0.341 0.252
E5-06
PM d-axis Inductance (mH/
phase)
mH 32.15 26.12 14.72 12.27 8.27 6.49

Table of Contents