Parameter List
3
3.22 Parameters Changed by E5-01 [PM Motor Code Selection]
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 209
No. Name Unit Motor Code (setting value of E5-01)
E5-07
PM q-axis Inductance (mH/
phase)
mH 41.74 34.30 20.15 14.77 9.81 7.74
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad 264.3 269.6 284.3 287.1 284.5 298.0
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-05 Maximum Output Voltage V 190.0 190.0 190.0 190.0 190.0 190.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5 72.5
E1-09 Minimum Output Frequency Hz 3.6 3.6 3.6 3.6 3.6 3.6
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.098 0.071 0.066 0.087 0.085 0.072
n5-02
Motor Inertia Acceleration
Time
s 0.098 0.071 0.066 0.087 0.085 0.072
n8-49 Heavy Load Id Current % -6.6 -10.9 -13.5 -9.0 -9.5 -10.1
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
Table 3.14 SSR1 Series Motor Code Setting for Specification of 200 V at 1450 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 130B 130D 130E 130F 1310
Voltage Class V 200 200 200 200 200
Capacity kW 7.5 11 15 18.5 22
Motor Rotation Speed min
-1
1450 1450 1450 1450 1450
E5-02 PM Motor Rated Power kW 7.5 11.0 15.00 18.50 22.00
E5-03 PM Motor Rated Current (FLA) A 27.71 39.6 55.5 65.6 75.1
E5-04 PM Motor Pole Count - 6 6 6 6 6
E5-05
PM Motor Resistance (ohms/
phase)
Ω 0.184 0.099 0.075 0.057 0.041
E5-06 PM d-axis Inductance (mH/phase) mH 6.91 4.07 3.29 2.53 1.98
E5-07 PM q-axis Inductance (mH/phase) mH 7.66 4.65 3.84 3.01 2.60
E5-09
PM Back-EMF Vpeak (mV/(rad/
s))
mVs/rad 335.0 303.9 311.2 300.9 327.7
E5-24
PM Back-EMF L-L Vrms (mV/
rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 72.5 72.5 72.5 72.5 72.5
E1-05 Maximum Output Voltage V 190.0 190.0 190.0 190.0 190.0
E1-06 Base Frequency Hz 72.5 72.5 72.5 72.5 72.5
E1-09 Minimum Output Frequency Hz 3.6 3.6 3.6 3.6 3.6
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.084 0.096 0.085 0.080 0.122
n5-02 Motor Inertia Acceleration Time s 0.084 0.096 0.085 0.080 0.122
n8-49 Heavy Load Id Current % -6.0 -9.3 -10.7 -13.2 -15.7
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.