Parameter List
3
3.22 Parameters Changed by E5-01 [PM Motor Code Selection]
YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING 213
Table 3.20 SSR1 Series Motor Code Setting for Specification of 400 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 143B 143D 143E 143F 1440 1442
Voltage Class V 400 400 400 400 400 400
Capacity kW 7.5 11 15 18.5 22 30
Motor Rotation Speed min
-1
1150 1150 1150 1150 1150 1150
E5-02 PM Motor Rated Power kW 7.5 11.0 15 18.50 22.00 30.00
E5-03
PM Motor Rated Current
(FLA)
A 13.33 19.9 27.8 31.8 37.2 52.1
E5-04 PM Motor Pole Count - 6 6 6 6 6 6
E5-05
PM Motor Resistance (ohms/
phase)
Ω 0.660 0.443 0.331 0.264 0.192 0.140
E5-06
PM d-axis Inductance (mH/
phase)
mH 26.36 19.10 15.09 13.32 9.52 8.16
E5-07
PM q-axis Inductance (mH/
phase)
mH 34.20 24.67 18.56 18.00 12.60 11.40
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad 783.0 762.2 749.6 842.7 821.8 872.3
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-05 Maximum Output Voltage V 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-09 Minimum Output Frequency Hz 2.9 2.9 2.9 2.9 2.9 2.9
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.088 0.073 0.062 0.091 0.092 0.125
n5-02
Motor Inertia Acceleration
Time
s 0.088 0.073 0.062 0.091 0.092 0.125
n8-49 Heavy Load Id Current % -15.3 -16.7 -14.9 -17.9 -15.9 -17.7
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.