3.22 Parameters Changed by E5-01 [PM Motor Code Selection]
212 YASKAWA TOEPYAIGA5001A GA500 DRIVE MAINTENANCE & TROUBLESHOOTING
No. Name Unit Motor Code (setting value of E5-01)
E5-06 PM d-axis Inductance (mH/phase) mH 6.59 4.96 3.83 3.33 2.38
E5-07 PM q-axis Inductance (mH/phase) mH 8.55 6.12 4.65 4.50 3.15
E5-09
PM Back-EMF Vpeak (mV/(rad/
s))
mVs/rad 391.5 384.4 372.1 421.3 410.9
E5-24
PM Back-EMF L-L Vrms (mV/
rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 57.5 57.5 57.5 57.5 57.5
E1-05 Maximum Output Voltage V 190.0 190.0 190.0 190.0 190.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5
E1-09 Minimum Output Frequency Hz 2.9 2.9 2.9 2.9 2.9
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.088 0.073 0.062 0.091 0.092
n5-02 Motor Inertia Acceleration Time s 0.088 0.073 0.062 0.091 0.092
n8-49 Heavy Load Id Current % -15.3 -13.9 -14.4 -17.9 -15.9
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.
Table 3.19 SSR1 Series Motor Code Setting for Specification of 400 V at 1150 min
-1
(r/min)
No. Name Unit Motor Code (setting value of E5-01)
E5-01
PM Motor Code Selection - 1432 1433 1435 1436 1438 143A
Voltage Class V 400 400 400 400 400 400
Capacity kW 0.4 0.75 1.5 2.2 3.7 5.5
Motor Rotation Speed min
-1
1150 1150 1150 1150 1150 1150
E5-02 PM Motor Rated Power kW 0.4 0.75 1.5 2.2 3.7 5.5
E5-03
PM Motor Rated Current
(FLA)
A 0.94 1.51 3.00 4.43 7.08 10.10
E5-04 PM Motor Pole Count - 6 6 6 6 6 6
E5-05
PM Motor Resistance (ohms/
phase)
Ω 19.320 10.800 4.456 2.044 1.483 1.215
E5-06
PM d-axis Inductance (mH/
phase)
mH 194.70 129.20 76.88 48.60 37.58 44.54
E5-07
PM q-axis Inductance (mH/
phase)
mH 252.84 160.90 97.52 61.40 47.65 56.26
E5-09
PM Back-EMF Vpeak (mV/
(rad/s))
mVs/rad 640.9 654.1 728.8 688.9 702.0 861.5
E5-24
PM Back-EMF L-L Vrms
(mV/rpm)
mV/min
-1
0.0 0.0 0.0 0.0 0.0 0.0
E1-04 Maximum Output Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-05 Maximum Output Voltage V 380.0 380.0 380.0 380.0 380.0 380.0
E1-06 Base Frequency Hz 57.5 57.5 57.5 57.5 57.5 57.5
E1-09 Minimum Output Frequency Hz 2.9 2.9 2.9 2.9 2.9 2.9
L3-24
*1
Motor Accel Time @ Rated
Torque
s 0.062 0.044 0.080 0.090 0.067 0.072
n5-02
Motor Inertia Acceleration
Time
s 0.062 0.044 0.080 0.090 0.067 0.072
n8-49 Heavy Load Id Current % -8.8 -9.9 -9.3 -10.0 -12.8 -12.3
*1 The default setting changes when the setting for o2-04 [Drive Model Selection] changes.