6.2Troubleshooting
353
Display and Outputs
Digital Operator
Alarm Output
Display and
Alarm Code Output
Alarm Output
arm
ame
ALO1 ALO2 ALO3
A.70
Overload
ON ON ON OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
B
,
C
,D
When speed reference
input
No servomotor
rotation
During normal
operation
At power ON
D
,E
E
When servo ON (S-ON)
signal turned ON
A
,B,D
Cause Remedy
A Servomotor wiring incorrect or
disconnected
Check wiring and connectors at
servomotor.
B Encoder wiring incorrect or disconnected Check wiring and connectors at encoder.
C Load greatly exceeds rated torque Reduce load torque and inertia. Otherwise,
replace with larger capacity servomotor.
D Incremental encoder power not supplied
from Servopack.
Use the Servopack power supply for the
encoder.
E Circuit board (1PWB) defective Replace Servopack.
6