INSPECTION, MAINTENANCE AND TROUBLESHOOTING
6.2.1 Troubleshooting Problems with Alarm Displaycont.
362
Display and Outputs
Digital Operator
Alarm Output
Display and
Alarm Code Output
Alarm Output
arm
ame
ALO1 ALO2 ALO3
A.C3
Encoder A-,
B-phase
discontinuity
ON OFF ON OFF
OFF: Output transistor is OFF
ON: Output transistor is ON
Status When Alarm Occurred
D
At power ON
User constant
Cn-01 Bit 0 = 0
When servo ON (S-ON)
signal turned ON
A
,B,C,D
During servomotor
operation
A, B, C, D
A
,B,C
Occurred 1 to 3 seconds
after power ON
User constant
Cn-01 Bit 0 = 1
Cause Remedy
A Encoder wiring incorrect or poor
connection
Check wiring and connectors at encoder .
B Noise in encoder wiring. Separate encoder wiring from main wiring
circuits.
C Encoder defective Replace servomotor.
D Circuit board (1PWB) defective Replace Servopack.
6