5 Operation
5.11.2 External Device Monitor (EDM1)
5-84
(1) Connection Example and Specifications of EDM1 Output Signal
Connection example and specifications of EDM1 output signal are explained below.
Connection Example
EDM1 output signal is used for source circuit.
Specifications
Electrical characteristics of EDM1 signal are as follows.
For safety function signal connections, the input signal is the 0V common and the output
signal is the source output. This is opposite to other signals described in this manual. To
avoid confusion, the ON and OFF status of signals for safety functions are defined as fol-
lows:
ON: The state in which the relay contacts are closed or the transistor is ON and current
flows into the signal line.
OFF: The state in which the relay contacts are open or the transistor is OFF and no cur-
rent flows into the signal line.
24 V Power Supply
SERVOPACK
CN8
External Device
EDM1+
EDM1-
0 V
8
7
Type Signal Name Pin No.
Output
Status
Meaning
Output EDM1
CN8-8
CN8-7
ON
Both baseblocks by /HWBB1 signal and /HWBB2 signal
normally activate.
OFF
Items Characteristics Remarks
Maximum Allowable Voltage 30 VDC
Maximum Current 50 m ADC
Maximum Voltage Drop at ON 1.0 V Voltage between EDM1+ to EDM1- at current is 50 mA.
Maximum Delay Time 20 ms
Time from change of /HWBB1, /HWBB2 to change of
EDM1