6 Adjustments
6.5.1 One-parameter Tuning
6-36
(1) Before Performing One-parameter Tuning
Check the following settings before performing one-parameter tuning.
a) A message (NO-OP) indicating that no operations are possible will be displayed, if all of the following
conditions are not met.
The tuning-less function must not be enabled.
Test without motor function must not be enabled. (Pn00C.0 = 0)
b) Observe the following condition to ensure operation.
The write prohibited setting (Fn010) must not be set.
The tuning mode must be set to 0 or 1 in speed control.
(2) Usage Restrictions
With this function, the following restrictions are applied in accordance with the version number of the SER-
VOPACK software version and the encoder resolution being used.
Application Restrictions When Using a 17-bit or 20-bit Encoder
Applicable servomotors : SGMV-D, SGMV-3
SGMPS-C, SGMPS-2
Application Restrictions by Model Following Control
The software version number of your SERVOPACK can be checked with Fn012.
Parameter Added from SERVOPACK’s Software Version 0008 or Later
Application Restrictions When Using a 13-bit Encoder
Applicable servomotor : SGMJV-A
Application Restrictions for Tuning Mode
The software version number of your SERVOPACK can be checked with Fn012.
SGDV SERVOPACK's Software Version *
SERVOPACK software
0007 or earlier
SERVOPACK software
0008 or later
Model following control type Type 1 Type 1 or Type 2 [Factory setting]
Application Restrictions
Position errors may easily result in
overshooting, so the positioning
time may be extended if the posi-
tioning completed width (Pn522)
is set to a small value.
Suppresses overshooting that
results from position errors more
efficiently than SERVOPACK
software 0007 or earlier. If com-
patibility with SERVOPACK soft-
ware 0007 or earlier is required,
select Model Following Control
Type 1 (Pn14F.0 = 0).
Parameter Function When Enabled Classification
Pn14F
n.0 Model following control type 1
After restart Tuning
n.1 Model following control type 2 [Factory setting]
SGDV SERVOPACK's Software Version *
SERVOPACK software
0007 or earlier
SERVOPACK software
0008 or later
Application Restrictions
The tuning mode can be used to
select only 0 or 1.
No restrictions

Table of Contents