Secure Your Gateway
Security Center
Configure Alert Settings
Upload Certificate Files
Configure Firewall Rules
Security Center
You can check TG gateway security configuration in “Security Center” page. And also, you can enter
the relevant security settings page rapidly.
Check the description of the service port below.
UDP Port used for SIP registrations. The default is 5060.
Port for login the web. The default port for HTTP is 80.
SSH port is used to access S-Series underlying configurations to debug the
system. The default port is 8022. We recommend that you disable SSH port if you
do not need it.
With FTP service, you can connect to PBX via web browser. The default port is
21.
TCP Port used for SIP registrations. The default is 5060.
TLS Port used for SIP registrations. The default is 5061.
Configure Alert Settings
You can set email notification or call notification for system IP attack and Web attack.
Configure IP Attack Alert Settings
When the TG gateway is attacked by an IP address, the system will add the IP to IP Blacklist and
send email notification or call notification to the desired users.
Procedure
1. Navigate to System > Security Center > Alert Settings, choose IP Attack Type and click .
2. Configure the Phone Notification Settings.
a. If you want to enable phone notification, set Phone Notification to Yes.
b. Choose one GSM/3G Port to make outbound calls.
c. Enter the Number to receive call notification.
d. (Optional) Change the alert call attempts, interval, and alert prompt.