EasyManua.ls Logo

YOKOGAWA DL850 ScopeCorder - When the Record Length Is 100 Mpoint, 250 Mpoint, 500 Mpoint, 1 Gpoint, or 2 Gpoint

YOKOGAWA DL850 ScopeCorder
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
App-12
IM DL850-03EN
When the Record Length Is 4 Gpoint, 5 Gpoint, 10 Gpoint, 20 Gpoint, or 50 Gpoint
Record Length
4 Gpoint 5 Gpoint 10 Gpoint 20 Gpoint 50 Gpoint
Time/div Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
Sample
Rate
(S/s)
Display
Record
Length
(Points)
1 μs
2 μs
5 μs
10 μs
20 μs
50 μs
100 μs
200 μs
500 μs
1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
3 s
4 s
5 s
6 s
8 s
10 s
20 s
30 s
1 min
2 min
3 min
4 min 1 M 2.4 G
5 min 1 M 3 G 1 M 3 G
6 min 1 M 3.6 G 1 M 3.6 G
7 min 500 k 2.1 G 1 M 4.2 G
8 min 500 k 2.4 G 1 M 4.8 G
9 min 500 k 2.7 G 500 k 2.7 G 1 M 5.4 G
10 min 500 k 3 G 500 k 3 G 1 M 6 G
12 min 500 k 3.6 G 500 k 3.6 G 1 M 7.2 G
15 min 200 k 1.8 G 500 k 4.5 G 1 M 9 G
30 min 200 k 3.6 G 200 k 3.6 G 500 k 9 G 1 M 18 G
1 h 100 k 3.6 G 100 k 3.6 G 200 k 7.2 G 500 k 18 G 1 M 36 G
2 h 50 k 3.6 G 50 k 3.6 G 100 k 7.2 G 200 k 14.4 G 500 k 36 G
3 h 20 k 2.16 G 20 k 2.16 G 50 k 5.4 G 100 k 10.8 G 200 k 21.6 G
4 h 20 k 2.88 G 20 k 2.88 G 50 k 7.2 G 100 k 14.4 G 200 k 28.8 G
5 h 20 k 3.6 G 20 k 3.6 G 50 k 9 G 100 k 18 G 200 k 36 G
6 h 10 k 2.16 G 20 k 4.32 G 20 k 4.32 G 50 k 10.8 G 200 k 43.2 G
7 h 10 k 2.52 G 10 k 2.52 G 20 k 5.04 G 50 k 12.6 G 100 k 25.2 G
8 h 10 k 2.88 G 10 k 2.88 G 20 k 5.76 G 50 k 14.4 G 100 k 28.8 G
9 h 10 k 3.24 G 10 k 3.24 G 20 k 6.48 G 50 k 16.2 G 100 k 32.4 G
10 h 10 k 3.6 G 10 k 3.6 G 20 k 7.2 G 50 k 18 G 100 k 36 G
12 h 5 k 2.16 G 10 k 4.32 G 20 k 8.64 G 20 k 8.64 G 100 k 43.2 G
1 day 2 k 1.728 G 5 k 4.32 G 10 k 8.64 G 20 k 17.28 G 50 k 43.2 G
2 days 2 k 3.456 G 2 k 3.456 G 5 k 8.64 G 10 k 17.28 G 20 k 34.56 G
3 days 1 k 2.592 G 1 k 2.592 G 2 k 5.184 G 5 k 12.96 G 10 k 25.9 G
When the time axis setting is 100 ms or greater (the settings surrounded by bold lines) and the trigger mode is Auto or Auto Level,
waveforms are displayed in roll mode.
Appendix 1 Relationship between the Time Axis Setting, Record Length, and Sample Rate

Table of Contents