3 Installation
980-001-0210G NetPath 100 User’s Manual - Installation Guide 3-9
June
1999
ITU-V.35 Adapter
Cable
Use CRC cable assembly # 135-001-0400, or per pinout shown in Table 3-4.
Table 3-4 ITU-V.35 Interface Adapter Cable (CBC=1)
M-34F
Pin
DB-44M
Pin
Si
nal Direction
M-34F
Pin
DB-44M
Pin
Si
nal Direction
A1ShieldN/A U 29 TCE-A Input
B 7 Sig. Gnd. N/A
V 27 RC-A Output
C 4 RTS(s) Input W 44 TCE-B Input
D5CTS(s)Output
X 42 RC-B Output
E 6 DSR(s) Output
Y 25 TC-A Output
F 8 DCD(s) Output Z
G
AA 40 TC-B Output
H 9 DTR(s) Input
BB
I CC
J
DD
K
EE
L FF
M
GG
N
HH
O II
P 17 TD-A Input
JJ
Q
KK
R 18 RD-A Output LL
S 32 TD-B Input
MM
T 33 RD-B Output
NN
26 CBC-A* N/A
28 to 22 CBC-B* N/A
30 to 22 CBC-C* N/A
Notes: *CBC = Cable Code pin.
(s) = single ended.
Twisted Pair cable conductors for: TD-A & B, RD-A & B, TC-A & B, RC-A & B and TCE-A & B.
Install 300 Ohm, 1/4W, 5% resistors at DB-44 end across pins: 17 to 37, 32 to 37, 29 to 22, and 44 to 22.
Shielded cable is recommended.