3 Installation
3-10 NetPath 100 Users Manual - Installation Guide 980-001-0210G
June
1999
EIA-530 Adapter
Cable
Use CRC cable assembly # 135-002-0400, or per pinout shown in Table 3-5.
Table 3-5 EIA-530 Interface Adapter Cable (CBC=2)
DB-25F
Pin
DB-44M
Pin
Si
g
nal Direction
DB-25F
Pin
DB-44M
Pin
Si
g
nal Direction
116ShieldN/A 14 32 TD-B Input
2 17 TD-A Input
15 25 TC-A Output
3 18 RD-A Output
16 33 RD-B Output
4 19 RTS-A Input 17 27 RC-A Output
520CTS-AOutput
18
621DSR-AOutput
19 34 RTS-B Input
7 22 Sig. Gnd. N/A 20 24 DTR-A Input
823DCD-AOutput
21
9 42 RC-B Output
22 36 DSR-B Output
10 38 DCD-B Output 23 39 DTR-B Input
11 44 TCE-B Input
24 29 TCE-A Input
12 40 TC-B Output
25
13 35 CTS-B Output
26 to 22 CBC-A* Cable Code - A
28 CBC-B* Cable Code - B
30 to 22 CBC-C* Cable Code - C
Notes: *CBC = Cable Code pin.
(s) = single ended.
Twisted Pair cable conductors for: TD-A & B, RD-A & B, RTS-A & B, CTS-A & B, DSR-A & B,
DCD-A & B, DTR-A & B, TC-A & B, RC-A & B and TCE-A & B.
Shielded cable is recommended.

Table of Contents