Chapter 37 Access Control
VES1724-56 User’s Guide
339
DdmiRxPowerAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
received optical power goes over the
“high alarm” threshold.
DdmiVoltageAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
voltage goes over the “high alarm”
threshold.
DdmiTxBiasAlarmEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
laser bias current goes over the “high
alarm” threshold.
DdmiTemperatureWarnEven
tOn
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
temperature goes over the “high
warning” threshold.
DdmiTxPowerWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
transmitted optical power goes over the
“high warning” threshold.
DdmiRxPowerWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
received optical power goes over the
“high warning” threshold.
DdmiVoltageWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
voltage goes over the “high warning”
threshold.
DdmiTxBiasWarnEventOn 1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.1
This trap is sent when a transceiver’s
laser bias current goes over the “high
warning” threshold.
DdmiTemperatureAlarmEve
ntCleared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
temperature falls down below the high
alarm threshold and is back to the
normal range.
DdmiTxPowerAlarmEventCle
ared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
transmitted optical power falls down
below the high alarm threshold and is
back to the normal range.
DdmiRxPowerAlarmEventCl
eared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
received optical power falls down below
the high alarm threshold and is back to
the normal range.
DdmiVoltageAlarmEventCle
ared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
voltage falls down below the high alarm
threshold and is back to the normal
range.
DdmiTxBiasAlarmEventClea
red
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
laser bias current falls down below the
high alarm threshold and is back to the
normal range.
DdmiTemperatureWarnEven
tCleared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
temperature falls down below the high
warning threshold and is back to the
normal range.
DdmiTxPowerWarnEventCle
ared
1.3.6.1.4.1.890.1.5.12.46.45.2
7.2.2
This trap is sent when a transceiver’s
transmitted optical power falls down
below the high warning threshold and is
back to the normal range.
Table 158 SNMP Interface Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION