EasyManua.ls Logo

ABB ACS355 series - Summary of the IO Connections of the Application Macros

ABB ACS355 series
436 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application macros 109
Summary of the I/O connections of the application macros
The following table gives the summary of the default I/O connections of all application
macros.
Input/
output
Macro
ABB
standard
3-wire Alternate Motor
potentiom.
Hand/Auto PID
control
Torque
control
AI1
(0…10 V)
Freq. ref. Speed ref. Speed ref. - Speed ref.
(Hand)
Proc. ref.
(PID) /
Freq. ref.
(Hand)
Speed ref.
(Speed)
AI2
(0…20 mA)
----Speed ref.
(Auto)
Process
value
To rq u e
ref.
(Torque)
AO Output
freq.
Speed Speed Speed Speed Speed Speed
DI1 Stop/Start Start
(pulse)
Start (fwd) Stop/Start Stop/Start
(Hand)
Stop/Start
(PID)
Stop/Start
(Speed)
DI2 Fwd/Rev Stop
(pulse)
Start (rev) Fwd/Rev Fwd/Rev
(Hand)
PID/Hand Fwd/Rev
DI3 Const.
speed
input 1
Fwd/Rev Const.
speed
input 1
Speed ref.
up
Hand/Auto Const.
speed 1
Speed/
To rq u e
DI4 Const.
speed
input 2
Const.
speed
input 1
Const.
speed
input 2
Speed ref.
down
Fwd/Rev
(Auto)
Run
enable
Const.
speed 1
DI5 Ramp pair
selection
Const.
speed
input 2
Ramp pair
selection
Const.
speed 1
Stop/Start
(Auto)
Stop/Start
(Hand)
Ramp pair
selection
RO Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1)
DO Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1) Fault (-1)

Table of Contents

Other manuals for ABB ACS355 series