384 Technical data
Terminal and lead-through data for the power cables
Terminal and lead-through data for the control cables
Frame
size
Max. cable
diameter for NEMA 1
U1, V1, W1, U2, V2, W2,
BRK+ and BRK-
PE
U1, V1, W1,
U2, V2, W2
BRK+ and
BRK-
Terminal size Tightening
torque
Clamp size Tightening
torque
mm in mm in mm
2
AWG N·m lbf·in mm
2
AWG N·m lbf·in
R0 16 0.63 16 0.63 4.0/6.0 10 0.8 7 25 3 1.2 11
R1 16 0.63 16 0.63 4.0/6.0 10 0.8 7 25 3 1.2 11
R2 16 0.63 16 0.63 4.0/6.0 10 0.8 7 25 3 1.2 11
R3 29 1.14 16 0.63 10.0/16.0 6 1.7 15 25 3 1.2 11
R4 35 1.38 29 1.14 25.0/35.0 2 2.5 22 25 3 1.2 11
00353783.xls L
Conductor size Tightening torque
Min/Max Min/Max
mm
2
AWG N·m lbf·in
0.25/1.5 24/16 0.5 4.4