218 Parameters
14.63 AI3 min (Visible when 14.01 Module 1 type = FIO-11)
Defines the minimum value for analog input AI3.
See also parameter 14.21 AI tune.
0.000 mA or
V
-22.000 … 22.000
mA or V
Minimum value of AI3. 1000 = 1 mA
or V
14.64 AI3 max (Visible when 14.01 Module 1 type = FIO-11)
Defines the maximum value for analog input AI3.
See also parameter 14.21 AI tune.
10.000 mA or
V
-22.000 … 22.000
mA or V
Maximum value of AI3. 1000 = 1 mA
or V
14.65 AI3 scaled at AI3
min
(Visible when 14.01 Module 1 type = FIO-11)
Defines the real value that corresponds to the minimum
analog input AI3 value defined by parameter 14.63 AI3 min.
0.000
-32768.000 …
32767.000
Real value corresponding to minimum AI3 value. 1 = 1
14.66 AI3 scaled at AI3
max
(Visible when 14.01 Module 1 type = FIO-11)
Defines the real value that corresponds to the maximum
analog input AI3 value defined by parameter 14.64 AI3 max.
See the drawing at parameter 14.65 AI3 scaled at AI3 min.
100.000
-32768.000 …
32767.000
Real value corresponding to maximum AI3 value. 1 = 1
14.71 AO force selection (Visible when 14.01 Module 1 type = FIO-11 or FAIO-01)
The value of the analog output can be overridden for eg.
testing purposes. A forced value parameter (14.78 AO1 force
data) is provided for the analog output, and its value is
applied whenever the corresponding bit in this parameter is 1.
00b
00b…11b Forced values selector for analog outputs. 1 = 1
No. Name/Value Description Def/FbEq16
14.66
14.64
14.63
14.65
AI
in
(14.56)
AI
scaled
(14.57)
Bit Name Description
0 AO1 1 = Force mode: Force AO1 to value of parameter 14.78 AO1 force data.
1 AO2 1 = Force mode: Force AO2 to value of parameter 14.88 AO2 force data
(FAIO-01 only).
3…15 Reserved