Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / real32Displays the value of speed reference before application
of critical speeds. See the control chain diagram on
page 745.
The value is received from 22.86 Speed reference act 6
unless overridden by
any constant speed
a jogging reference
network control reference (see Terms and
abbreviations (page 20))
control panel reference
safe speed reference.
This parameter is read-only.
Speed reference act
7
22.87
- / -Speed reference before application of critical speeds.
For scaling, see parameter 46.1.
-30000.00 ...
30000.00 rpm