Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
17Pt1000 sensor connected to encoder interface 2. See
parameters 91.24 Module 2 temp sensor type and 91.25
Module 2 temp filter time.
Note: Pt1000 sensor supports FEN-11 and FEN-31
encoder modules only.
Pt1000 encoder
module 2
130 ° / real32Defines the fault limit for temperature monitoring
function 1.
When measured temperature 1 exceeds the limit, the
drive trips on fault 4981 External temperature 1.
The unit is selected by parameter 96.16 Unit selection.
Note: With °F, the range is -76…1832. With a PTC sensor,
the range is 0…5000 ohms.
Temperature 1 fault
limit
35.12
1 = 1 ° / 1 = 1 °Fault limit for temperature monitoring function 1.-60...1000 °
110 ° / real32Defines the warning limit for temperature monitoring
function 1. When measured temperature 1 exceeds this
limit, a warning (A491 External temperature 1) is
generated.
The unit is selected by parameter 96.16 Unit selection.
Note: With °F, the range is -76…1832. With a PTC sensor,
the range is 0…5000 ohms.
Temperature 1
warning limit
35.13
1 = 1 ° / 1 = 1 °Warning limit for temperature monitoring function 1.-60...1000 °
Not selected / uint32Specifies the analog input when the setting of 35.11
Temperature 1 source requires measurement through
an analog input.
Note: If the input is located on an I/O extension module,
use the selection
Other
to point to the AI actual value
in group 14, 15 or 16, eg. 14.26 AI1 actual value.
Temperature 1 AI
source
35.14
0None.Not selected
1Analog input AI1 on the control unit.AI1 actual value
2Analog input AI2 on the control unit.AI2 actual value
See Terms and abbreviations (page 169).Other [value]
0 ° / real32Defines the calibration of temperature 1.
Calibration can be used to fine-tune the motor
temperature measurement. Once the motor has cooled
down, measure its ambient temperature and set this
value accordingly.
This parameter affects only if Pt100 or Pt1000
measurement is using AI and AO of the control unit or
I/O extension modules.
Temperature 1
calibration
35.17
1 = 1 ° / 1 = 1 °Calibration of temperature 1 in celsius.-30...1000 °
Parameters 401

Table of Contents