Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
3Reference REF2 (16 bits)Ref2 16bit
See Terms and abbreviations (page 169).Other [value]
None / uint32Defines a target for the data received as word 2 of data
set 10.
See also parameter 62.102 Data set 10 data 2 value.
For the selections, see parameter 62.51 Data set 10
data 1 selection.
Data set 10 data 2
selection
62.52
None / uint32Defines a target for the data received as word 3 of data
set 10.
See also parameter 62.103 Data set 10 data 3 value.
For the selections, see parameter 62.51 Data set 10
data 1 selection.
Data set 10 data 3
selection
62.53
None / uint32See parameter 62.51 Data set 10 data 1 selection.Data set 12 data 1
selection
62.54
None / uint32See parameter 62.51 Data set 10 data 1 selection.Data set 24 data 3
selection
62.74
0 / uint16Displays (in integer format) the data received from the
external controller as word 1 of data set 1.
A target for this data can be selected by parameter
62.45 Data set 1 data 1 selection. The value can also be
used as a source by another parameter.
Data set 1 data 1
value
62.95
- / -Data received as word 1 of data set 1.0...65535
0 / uint16Displays (in integer format) the data received from the
external controller as word 2 of data set 1.
A target for this data can be selected by parameter
62.46 Data set 1 data 2 selection. The value can also be
used as a source by another parameter.
Data set 1 data 2
value
62.96
- / -Data received as word 2 of data set 1.0...65535
0 / uint16Displays (in integer format) the data received from the
external controller as word 3 of data set 1.
A target for this data can be selected by parameter
62.47 Data set 1 data 3 selection. The value can also be
used as a source by another parameter.
Data set 1 data 3
value
62.97
- / -Data received as word 3 of data set 1.0...65535
0 / uint16Displays (in integer format) the data received from the
external controller as word 3 of data set 3.
A target for this data can be selected by parameter
62.50 Data set 3 data 3 selection. The value can also be
used as a source by another parameter.
Data set 3 data 3
value
62.100
- / -Data received as word 3 of data set 3.0...65535
- / uint16Displays (in integer format) the data received from the
external controller as word 1 of data set 10.
A target for this data can be selected by parameter
62.51 Data set 10 data 1 selection. The value can also
be used as a source by another parameter.
Data set 10 data 1
value
62.101
Parameters 517