EasyManua.ls Logo

ABB ACS880 - Page 588

ABB ACS880
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Auto rising / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.12 Speed calculation mode.
Speed calculation
mode
93.12
0 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.13 Position data width.
Position data width93.13
Enable / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.13 Position estimation enable.
Position estimation
enable
93.13
0 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.14 Revolution data width.
Revolution data
width
93.14
Disable / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.14 Speed estimation enable.
Speed estimation
enable
93.14
4880Hz / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.15 Transient filter.
Transient filter93.15
300 kHz / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.17 Accepted pulse freq of encoder 1.
Accepted pulse freq
of encoder 2
93.17
A, B / uint16(Visible when 93.1 Encoder 2 type = HTL 1)
See parameter 92.21 Encoder cable fault mode.
Encoder cable fault
mode
93.21
No filtering / uint16(Visible when 93.1 Encoder 2 type = HTL)
See parameter 92.24 Pulse edge filtering.
Pulse edge filtering93.24
Initial position /
uint16
(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.30 Serial link mode.
Serial link mode93.30
50 ms / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.31 EnDat max calculation time.
EnDat calc time93.31
100 us / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.32 SSI cycle time.
SSI cycle time93.32
2 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.33 SSI clock cycles.
SSI clock cycles93.33
1 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.34 SSI position msb.
SSI position msb93.34
1 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.35 SSI revolution msb.
SSI revolution msb93.35
Binary / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.36 SSI data format.
SSI data format93.36
100 kBit/s / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.37 SSI baud rate.
SSI baud rate93.37
315-45 deg / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.40 SSI zero phase.
SSI zero phase93.40
Odd / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.45 Hiperface parity.
Hiperface parity93.45
4800 bits/s / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.46 Hiperface baud rate.
Hiperface baud rate93.46
64 / uint16(Visible when 93.1 Encoder 2 type = Absolute encoder)
See parameter 92.47 Hiperface node address.
Hiperface node
address
93.47
588 Parameters