Parameters and firmware blocks
200
(4) 2 PROBE DIST Distance correction with two probes.
(5) COR M/F DIST Master/Follower distance correction.
62.15 TRIG PROBE1 FW block: CYCLIC CORRECTION (see above)
Defines the source of the latching command for position probe 1.
(0) DISABLED None.
(1) ENC1 DI1 _- Rising edge of encoder 1 digital input DI1.
(2) ENC1 DI1 -_ Falling edge of encoder 1 digital input DI1.
(3) ENC1 DI2 _- Rising edge of encoder 1 digital input DI2.
(4) ENC1 DI2 -_ Falling edge of encoder 1 digital input DI2.
(5) Reserved.
(6) ENC1 ZEROP Rising edge of encoder 1 Z-pulse.
(7) ENC1 DI1_- Z First rising edge of encoder 1 Z-pulse after the rising edge of encoder
1 digital input DI1.
(8) ENC1 DI1-_ Z First rising edge of encoder 1 Z-pulse after the falling edge of encoder
1 digital input DI1.
(9) ENC1 DI1=1 Z First rising edge of encoder 1 Z-pulse when encoder 1 digital input DI1
= 1.
(10) ENC1 DI1=0 Z First rising edge of encoder 1 Z-pulse when encoder 1 digital input DI1
= 0.
(11) ENC1 DI2_- Z First rising edge of encoder 1 Z-pulse after the rising edge of encoder
1 digital input DI2.
(12) ENC1 DI2-_ Z First rising edge of encoder 1 Z-pulse after the falling edge of encoder
1 digital input DI2.
(13) ENC1 DI2=1 Z First rising edge of encoder 1 Z-pulse when encoder 1 digital input DI2
= 1.
(14) ENC1 DI2=0 Z First rising edge of encoder 1 Z-pulse when encoder 1 digital input DI2
= 0.
(15) ENC2 DI1 _- Rising edge of encoder 2 digital input DI1.
(16) ENC2 DI1 -_ Falling edge of encoder 2 digital input DI1.
(17) ENC2 DI2 _- Rising edge of encoder 2 digital input DI2.
(18) ENC2 DI2 -_ Falling edge of encoder 2 digital input DI2.
(19) Reserved.
(20) ENC2 ZEROP Rising edge of encoder 2 Z-pulse.
(21) ENC2 DI1_- Z First rising edge of encoder 2 Z-pulse after the rising edge of encoder
2 digital input DI1.