Parameters and firmware blocks
201
(22) ENC2 DI1-_ Z First rising edge of encoder 2 Z-pulse after the falling edge of encoder
2 digital input DI1.
(23) ENC2 DI1=1 Z First rising edge of encoder 2 Z-pulse when encoder 2 digital input DI1
= 1.
(24) ENC2 DI1=0 Z First rising edge of encoder 2 Z-pulse when encoder 2 digital input DI1
= 0.
(25) ENC2 DI2_- Z First rising edge of encoder 2 Z-pulse after the rising edge of encoder
2 digital input DI2.
(26) ENC2 DI2-_ Z First rising edge of encoder 2 Z-pulse after the falling edge of encoder
2 digital input DI2.
(27) ENC2 DI2=1 Z First rising edge of encoder 2 Z-pulse when encoder 2 digital input DI2
= 1.
(28) ENC2 DI2=0 Z First rising edge of encoder 2 Z-pulse when encoder 2 digital input DI2
= 0.
62.16 PROBE1 POS FW block: CYCLIC CORRECTION (see above)
Defines the reference position for position probe 1.
The unit depends on parameter 60.05 POS UNIT selection.
-32768…32768 Reference position for position probe 1.
62.17 TRIG PROBE2 FW block: CYCLIC CORRECTION (see above)
Defines the source of the latching command for position probe 2.
For selection, see parameter 62.15 TRIG PROBE1.
62.18 PROBE2 POS FW block: CYCLIC CORRECTION (see above)
Defines the reference position for position reference probe 2.
The unit depends on parameter 60.05 POS UNIT selection.
-32768…32768 Reference position for position probe 2.
62.19 MAX CORRECTION FW block: CYCLIC CORRECTION (see above)
Defines the maximum absolute value for cyclic correction. Example: If maximum value is set to 50
revolutions and the requested cyclic correction is 60 revolution, no correction is made.
The unit depends on parameter 60.05 POS UNIT selection.
0…32768 Maximum absolute value for cyclic correction.