EasyManua.ls Logo

ABB ACSM1 - Page 207

ABB ACSM1
448 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters and firmware blocks
207
Bit 2 1 = Positioning to the target position along the shortest path, regardless of bit 0 and 1 values.
0 = Positioning to the target position according to bits 0 and 1.
Bit 3 1 = Before the positioning is started, the position system is reset.
0 = The position system is not reset.
Bit 4 1 = Selected target position is absolute. (Always the same position reference).
0 = Selected target position is relative as defined by bit 6.
Bit 5 1 = Before the positioning is started, the position system is returned to the rollover axis range, i.e.
between 0…1 revolutions.
0 = The position system is not returned into the rollover axis range.
t
s
v
v
s
t
Actual pos. 9
Pos. reference 300°
A
B
A = Shortest path from 90° -> 180°: 90° + 90° = 180°
B = Shortest path from 90° -> 300°: 90° - 150° = 300°
Actual pos. 90°
Pos. reference 180°
4.13 POS REF IPO
4.01 SPEED REF POS
65.03 POS START 1
s
t
4.13 POS REF IPO
65.03 POS START 1
s
t
1.12 POS ACT
65.03 POS START 1
s
t
1.12 POS ACT
65.03 POS START 1
11.2 rev
0.2 rev
s
t
1.12 POS ACT
65.03 POS START 1

Table of Contents

Other manuals for ABB ACSM1

Related product manuals