Parameters and firmware blocks
215
(4) FBA REF2 Fieldbus reference 2.
(5) D2D REF1 Drive-to-drive reference 1.
(6) D2D REF2 Drive-to-drive reference 2.
(7) Reserved.
(8) POS 2ND ENC Encoder 2.
(9) VIRT MAST Virtual master reference.
67.02 SPEED REF VIRT M FW block: SYNC REF SEL (see above)
Selects the source for the virtual master speed reference.
(0) ZERO Zero position reference.
(1) AI1 Analogue input 1.
(2) AI2 Analogue input 2.
(3) FBA REF1 Fieldbus reference 1.
(4) FBA REF2 Fieldbus reference 2.
(5) D2D REF1 Drive-to-drive reference 1.
(6) D2D REF2 Drive-to-drive reference 2.
(7) ENC1 SPEED Encoder 1.
(8) ENC2 SPEED Encoder 2.
67.03 INTERPOLAT MODE FW block: SYNC REF SEL (see above)
Selects whether the synchronisation reference selected by parameter 67.01 SYNC REF SEL is
interpolated or not. This function can be used to smooth out short breaks in the reference.
(0) NONE Interpolation is not used. The synchronisation reference is reflected
directly by actual signal 4.15 SYNC REF UNGEAR.