Profibus DP 3.2
24 Product Specification RobotWare for BaseWare OS 3.2
3.7 Profibus DP 3.2
With a Profibus-DP Master/Slave board (DSQC368) in the S4C controller it is
possible to connect many sets of in- and output I/O units via the serial Profibus-DP
field bus net, and all the Profibus-DP signals are handled and addressed in the same
way as any other distributed I/O signal.
The maximum number of I/O units that can be defined in the S4C system is described
in Users Guide Baseware chapter I/O data specification. As I/O units counts all DP-
slave units connected to the S4C DP-master, the DP-slave, simulated I/O
units and other I/O units connected to other S4C fieldbuses.
It is possible to connect digital and/or analog in- and output I/O units on the
DSQC368 master bus. All I/O units must fulfil the DIN 19245 Part 3 Profibus
Specification - DP and must be certified by PNO
1
.
1. Profibus Nutzer Organization