EasyManua.ls Logo

ABB IRB 6400R - Interbus-S, Slave DSQC 351

ABB IRB 6400R
481 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting Tools
Product Manual 23
2.11 Interbus-S, slave DSQC 351
Designation Colour Description/Remedy
POWER-24 VDC Green Indicates that a supply voltage is present,
and has a level above 12 VDC.
NS/MS Green/red See section 2.14.
CAN Tx/CAN Rx Green/red See section 2.14.
POWER- 5 VDC Green Lit when both 5 VDC supplies are within
limits, and no reset is active.
RBDA Red Lit when this Interbus-S station is last
in the Interbus-S network.
If not as required, check parameter setup.
BA Green Lit when Interbus-S is active.
If no light, check network, nodes and
connections
RC Green Lit when Interbus-S communication
runs without errors.
Bus status LED’s
DSQC 351
ABB Flexible Automation
POWER
CAN Tx
CAN Rx
NS
MS
POWER
RC
RBDA
BA
Interbus-S
X3
X5
X21
X20
POWER
CAN Tx
MS
NS
RC
POWER
RBDA
BA
CAN Rx

Table of Contents