NoteAction
xx1500002016
Remove the protection cap from the nipple
of the oil filling plug and connect the oil
dispenser.
6
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Refill the gearbox with oil, using the oil
dispenser.
Note
The amount of oil to be filled depends on
the amount previously being drained.
7
See Type and amount of oil in gearboxes
on page 140.
Required oil level is: 0 - 10 mm below the
oil plug hole.
Inspect the oil level.8
See Inspecting the oil level in axis-4
primary gearbox on page 110.
xx1500002018
xx1500002016
Remove the oil dispenser and refit the
protection cap to the nipple of the oil filling
plug.
9
Continues on next page
Product manual - IRB 8700 157
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
3 Maintenance
3.4.4 Changing oil, axis-4 primary gearbox
Continued