xx1700001292
Required oil level is when the oil level is
visible just below the lower edge of the in-
spection hole, with axis-5 approximately
jogged +82° from the starting position.
9
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Add or drain oil, if required.10
Further information about how to drain or
fill with oil is found in section Changing oil,
axis-6 gearbox on page 168.
Tightening torque: 24 NmRefit the oil plug.11
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section First test
run may cause injury or damage on
page 27.
12
172 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
3 Maintenance
3.4.7 Changing oil, axis-6 gearbox
Continued

Table of Contents

Related product manuals