Required consumables
NoteArticle numberConsumable
-Cable ties
Flange sealantLoctite 574
Sikaflex
Refitting the cable harness
Use these procedures to refit the cable harness.
Refitting the cable harness in the base
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Attachment screws: M6x16 stainless steel
A2-70 (4 pcs)
Refit the connection plate in the base (if it
has been removed).
2
Tightening torque: 6 Nm
xx1500003088
Use caution and run the cable harness
through the hole in the frame and out to
the base plate.
3
Continues on next page
216 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued