EasyManua.ls Logo

ABB IRB 8700 Series - Page 216

ABB IRB 8700 Series
848 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Required consumables
NoteArticle numberConsumable
-Cable ties
Flange sealantLoctite 574
Sikaflex
Refitting the cable harness
Use these procedures to refit the cable harness.
Refitting the cable harness in the base
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Attachment screws: M6x16 stainless steel
A2-70 (4 pcs)
Refit the connection plate in the base (if it
has been removed).
2
Tightening torque: 6 Nm
xx1500003088
Use caution and run the cable harness
through the hole in the frame and out to
the base plate.
3
Continues on next page
216 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued

Table of Contents

Related product manuals