EasyManua.ls Logo

ABB IRB 8700 Series - Page 217

ABB IRB 8700 Series
848 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
A
B
C
F
E
D
xx1500003081
A Cables down through hole in frame,
to base plate
B Axis-2 motor cables
C SMB/BU cables
D Cables up through lower arm and
onwards
E Axis-3 motor cables
F Axis-1 motor cables
Make sure that the cables from the axis-1
bracket, runs untangled to all connection
points:
down through the hole in the frame
to the base plate,
to the axis-1 motor,
to the axis-2 motor,
to the axis-3 motor
to the SMB/BU recess.
Adjust the cables if needed. The different
cables must not be twisted or tangled.
Do not fasten the axis-1 bracket yet.
4
A
B
xx1600000078
A Bar code
B Hole for pin 1
Before refitting the R1.MP-A and R1.MP-B
contacts make sure that the hole for pin 1,
as well as the bar code, will be on the left
side. See figure.
5
xx1500003083
Refit the R1.MP-A and R1.MP-B contacts.
Note
Run the cables on top of each other,
through the base, without being twisted.
6
Screws M6x20 stainless steel (4 pcs)
Make sure the signal cable R1.SMB runs
under the oil hose and above the R1.MP
cables, through the base.
7
Continues on next page
Product manual - IRB 8700 217
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued