NoteAction
Sleeve KM nut D=152 L=220: 3HAC038174-
067
xx1500002726
Use a Sleeve KM nut to release the torque
on one of the KM nuts.
Note
Do not remove this KM nut at this point.
Only release the torque.
6
xx1500002727
Use the Sleeve KM nut, open and remove
the KM nut on the other side.
Note
Make sure not to lose gamma sealing and
sealing ring.
7
Note
Continue the removal on the same side
until the shaft is removed completely.
Leave the other shaft fitted for now!
8
xx1500002728
Remove gamma sealing and sealing ring.9
Continues on next page
Product manual - IRB 8700 459
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.5.7 Replacing the parallel arm
Continued