Remove the magnetic plug and wipe hole
and shaft end meticulously clean.
10
Glycerine adapter
xx1600000081
Attach the Glycerine adapter.
Note
Tighten the adapter very hard in order to
avoid leakage.
11
xx1500002729
Remove the small VK cover.12
Continues on next page
460 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.5.7 Replacing the parallel arm
Continued