Loading...
NoteArticle numberEquipment, etc.
Used to push out the motor if neces-
sary.
Always use removal tools in pairs.
3HAC14631-1Removal tool M12
Content is defined in section Standard
toolkit on page 833.
-Standard toolkit
Required consumables
NoteArticle numberConsumable
Castrol Molub. Alloy 777-1 NG, 5
ml. To be used on hub splines to
prevent from fretting corrosion.
3HAC063069-001Grease
Loctite 57412340011-116Flange sealant
-Cable ties
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
NoteAction
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in Reference calibration
routine on page 806.If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Removing the motor
Use these procedures to remove the motor.
Preparations before removing the axis-5 motor
NoteAction
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
Continues on next page
602 Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.7.4 Replacing the axis-5 motor
Continued

Table of Contents