Performing a leak-down test
NoteAction
See Performing a leak-down test on
page 184.
Perform a leak-down test.1
Preparations before refitting the axis-1 motor
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure and air pressure are turned
off.
1
Remove old paint residues and other contamina-
tion from the contact surfaces on both motor and
gearbox.
2
Wipe clean the contact surfaces from any remain-
ing contamination.
3
Also wipe clean the o-ring groove.
O-ring, 3HAB3772-107
xx1200001019
Inspect the o-ring.
Note
Replace if damaged.
4
xx1200001020
Make sure the o-ring is seated in the groove.
Tip
Lubricate the o-ring with some grease for a better
fitting in the groove.
5
Continues on next page