NoteAction
Tip
To make sure that all screws in this area are
torqued, use a marker pen and mark each screw
after it has been torqued.
3
Examine that all screws in this area now has been
torqued.
4
Concluding procedure
NoteAction
See Performing a leak-down test on
page 184.
Perform a leak-down test (if not already
done).
1
See Changing oil in axis-2 and axis-3
gearbox on page 147.
Refill the gearbox with oil.2
Axis Calibration is described in Calibrating
with Axis Calibration method on page 805.
Recalibrate the robot.3
General calibration information is included
in section Calibration on page 795.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section First test
run may cause injury or damage on
page 27.
4
Product manual - IRB 8700 759